LNG-Hydrogen
Flange Insulation Kits for LNG and Hydrogen
Flange insulation kits (Insulating Gaskets) for the transport and storage of LNG (Liquefied Natural Gas) and Hydrogen ensure max dielectric isolation and cryogenic resistance, providing galvanic corrosion protection even at extreme temperatures down to -196 °C.
Ideal for cryogenic plants, storage tanks, LNG carriers, high-pressure pipelines, and liquid or compressed hydrogen distribution systems.
Resistant to cryogenic temperatures
Selected materials maintain flexibility and performance even at -196 °C without compromising sealing integrity
Compatible with high-purity technical gases
made from non-contaminating materials, ideal for applications where maintaining the purity of the transported fluid is essential
Complete electrical insulation
prevent arc discharges and stray currents, protecting pipelines and metal structures in highly conductive environments
Safety during transport and storage
designed to withstand shocks, vibrations, and thermal variations, ensuring reliability even under dynamic conditions
Products
Insulating gasket kit FIK Drain
Dielectric insulation and effective sealing
The flange insulation kit, combined with the safety flange cover MSC Drain Flex - V2, guarantees optimal dielectric insulation, cathodic protection and an effective sealing of the flanged joint, contributing to the safety of the system and environmental protection by preventing the formation of galvanic currents.
- Min/max temperature: -210 +260 °C
- Max pressure: 76 bar

Insulating gasket kit FIK 5
Flange insulation kit for extreme conditions (high pressure/cryogenics)
The Flange Insulation Kit (gasket insulation) FIK 5 ensures sealing and electrical insulation in extreme operating conditions, such as high pressure (up to 500 bar) and cryogenic temperatures (-210 °C). Its configuration is particularly suitable for hydrogen and LNG systems, both in liquid and gaseous state.
- Min/max temperature: -210 +260 °C
- Max pressure: 500 bar